Entry Time:2019-05-17 10:17:25
Technical Specifications for hydrogen generator by water electrolysis Model: ZDQ-5 ~ 12 and CNDQ-5~12 |
||||
Model |
ZDQ-5 |
ZDQ-6 |
ZDQ-8 |
ZDQ-10 |
H2Output (Nm3/h) |
5 |
6 |
8 |
10 |
O2Output (Nm3/h) |
2.5 |
3 |
4 |
5 |
Hydrogenpurity (V/V) |
≥99.8% |
|||
Oxygenpurity (V/V) |
≥99.2% |
|||
Working pressure (MPa) |
1.5~3.2 |
|||
Water content in H2 |
≤4 g/Nm3 |
|||
Alkali content in H2 |
≤1 mg/Nm3 |
|||
Operation temperature(℃) |
85±5(asbestos) / 95±5(non-asbestos) |
|||
Rated DC current (A) |
350 |
|||
Rated DC Voltage(V) |
36 |
44 |
56 |
72 |
Quantity of cells |
36 |
44 |
56 |
72 |
Cooling water consumption (m3/h) |
1.3 |
1.4 |
1.6 |
1.9 |
DCPower consumption |
≤4.60kWh/Nm3H2 |
|||
Alkaline concentration |
30%KOH(by weight) |
|||
Instrumentation Air pressure |
0.5~0.7MPa |
|||
IAconsumption |
5.0Nm3/h |
|||
Main power capacity(KVA) |
40 |
50 |
60 |
75 |
Main power voltage |
380VAC (50Hz)Transformer in the rectifier cabinet |
|||
Rectifier power supply |
||||
Control cabinet power supply |
6kw380VAC50Hz |
|||
Cooling water temp |
≤32℃ |
|||
Cooling water pressure |
0.4~0.6MPa |
|||
Cooling water quality |
≤6 German degree |
|||
Room temperature |
0~45℃ |
|||
Dimension of rectifier |
1000 x 800 x 2200 (mm) |
|||
Dimension of control panel |
800 x 800 x 2200(mm) |