Technical Specifications for hydrogen generator by water electrolysis Model: ZDQ-100 ~ ZDQ-150
|
||||
Model |
ZDQ-100 |
ZDQ-120 |
ZDQ-125 |
ZDQ-150 |
H2 Output(Nm3/h) |
100 |
120 |
125 |
150 |
O2 Output(Nm3/h) |
50 |
60 |
62.5 |
75 |
Hydrogen purity |
≥99.8%(V/V) |
|||
Oxygen purity |
≥99.2%(V/V) |
|||
Working pressure(MPa) |
1.5~3.2 (asbestos) / 1.5~2.0 (non-asbestos) |
|||
Water content in H2 |
≤4 g/Nm3 H2 |
|||
Alkali content in H2 |
≤1 mg/Nm3 H2 |
|||
Operation temperature |
85±5℃(asbestos) / 95±5℃(non-asbestos) |
|||
Rated DC current |
2120A |
|||
Rated DC Voltage (V) |
232 |
280 |
288 |
344 |
Quantity of cells |
116 |
140 |
144 |
172 |
Cooling water consumption(m3/h) |
15 |
20 |
21 |
25 |
DC Power consumption |
≤4.60kWh/Nm3H2 |
|||
Alkali concentration |
30%KOH (by weight) |
|||
Instrumentation Air pressure |
0.5-0.7MPa |
|||
IA consumption |
5.0Nm3/h |
|||
Main power capacity (KVA) |
700 |
850 |
850 |
1000 |
Main power voltage |
6kV or 10kV(50Hz) |
|||
Rectifier power supply |
1.0KW 380VAC 50Hz |
|||
Control cabinet power supply |
10KW 380V 50Hz |
|||
Cooling water temp |
≤32℃ |
|||
Cooling water pressure |
0.4-0.6MPa |
|||
Cooling water quality |
≤6 German degree |
|||
Room temperature |
0-45℃ |
|||
Dimension of rectifier |
1200 x 800 x 2200 (mm) |
|||
Dimension of control panel |
800 x 800 x 2200 (mm) |